Funnelle Elevator #1 is currently down and Schindler Elevator has been notified. Elevator Technician is on site MondayWednesday and Friday. Technician will respond to this call on Friday, March 2nd, 2018. HM-340703, reference #59451084. 

Update:

On 3/2/18, Schindler's Technician found intermittent door lock errors. He replaced safe 1&2 relays. Cleaned all sills. Open, cleaned and checked all door lock contacts, replaced contacts as needed. Car is running.  

Location

Funnelle Hall

Date

Mar 1 2018 - 8:30am to Mar 5 2018 - 9:45am

Outage type

Unplanned